Environment Projects
Description
?
Sodium Hypochlorite Generator Brine Electrolysis For Hosptial Disinfection
?
?
Technical parameters:
?
- - - -
Type | Av.CL2 Capacity
?(g/h) | Flow Rate
?(L/h) | Salt Consumption
?(kg/d) | Water
Consumption
(m3/d) | Rated power
?(kw ) | Unite size
?(L×W×H)
(mm) |
CNJY-S-100 | 100 | 13 | 8.4 | 0.31 | 0.6 | 1200×800×1400 |
CNJY-S-200 | 200 | 25 | 16.8 | 0.6 | 1.2 | 1200×800×1400 |
CNJY-S-300 | 300 | 38 | 25.2 | 0.91 | 1.8 | 1200×800×1400 |
CNJY-S-400 | 400 | 50 | 33.6 | 1.2 | 2.4 | 1200×800×1400 |
CNJY-S-500 | 500 | 63 | 42 | 1.51 | 3 | 1200×800×1400 |
- - - -
?
Note:System requirements with salt and water
?
- - - -
Salt requirements: | ? |
Name | Request content( %) |
(NaCl) | >99.3 % |
(Fe) | <0.002% |
(Ca Mg) | <0.023% |
(Mn) | <0.00003% |
(Pb) | <0.0007% |
(Cu) | <0.0003% |
(F) | <0.01% |
? | Water requirements:
1)Operating water temperature:
The temperature between (18?C-23?C)is best. If do not use temperature regulation, please allow the temperature between (10?C-27?C),or a heating?exchanger or chiller equipment to be used for adjust the water temperature.
2)Operating water pressure:
Minimum 0.2 MPa, Maximum 0.35 Mpa, if not in this scope, need to increase a he pressure or vacuum equipment
3)water quality requirements:
pH 6.5 to 8.5
hardness[in calcium carbonate] < 5 ppm (soft water equipment outlet)
COD(Mn) < 1.5 ppm
Fe < 0.2 ?ppm
Mn < 0.01 ppm
Ni < 5 ppm
F <2 ppm
Cu < 5 ppb |
- - - -
?
?
Product introduction:
?
Generation principle:
?
? ? The revolutionary CNJY-S series sodium hypochlorite generator is a newly and for on-site product of NaClO equipment and use for all kinds of needed NaClO disinfected. Its working principle is :the sodium chloride solution under the certain voltage effect of the cell, a series of electrochemical reaction within the cell and the resulting solution is the NaClO solution. The main process can be simplified as follows:
?
The electrode reaction:
anode:2Cl--2e→Cl2
cathode:2H++2e→H2
solution:2NaOH+Cl2→NaCl+NaClO+H2O
?
Work flow chart:
?
?
Product components system
?
A, inlet water distribution system
Main components: water pressure gauge, water softener, soft water pump, water meter, salt tank, salt water pump and related piping and valves.
?
B, The power control system:
Including control cabinet, rectifier and cable connection.
?
C, Storage and dosing system
Including electrolytic cell, NaClO tank, dosing pump, piping and valves.
?
?
?
Advantage of on-site sodium hypochlorite generator
?
SAFETY:
Material safety: Salt, Water and Electricity as raw materials, no need for transportation of dangerous chemicals;
Product safety: Product-0.8% NaCIO solution, has the advantage of stable and safety, cost effective in operation and no attenuation in storage.
ENERGY-SAVING:
Make use of electricity in the off-peak period to generate the NaCIO solution.
ENVIRONMENTAL PROTECTION:
Avoid of usage, transportation of dangerous chemical material.
High current efficiency ,few by-product, safe H2 ventilation.
ECONOMY:
JIAYU equipment can largely reduce the operation cost compared to the bulk hypochlorite
?
TAG:
Sodium hypochlorite generator, On-site sodium hypochlorite
?
?
DETAILS:
?
?
?
?
Read More
Shanghai Jiayu Environmental Technology Co., LTD
Sodium Hypochlorite Generator,On Site Sodium Hypochlorite Generation,Sodium Hypochlorite Generation System
Address: Xuhui District (East China University of Science and Technology Parks) Huajing Road 1305, Lane on the 10th floor, Block B 3,
Shanghai, Shanghai
China, 200000
Tel: 86-21-61280157
Fax: 86-21-61280157