Others

Share us

500g/h Sodium Hypochlorite Water Treatment Sea Water Electrolysis Of Brine

CNJY-S

Description

?

500g/h Sodium Hypochlorite Water Treatment Sea Water Electrolysis Of Brine

?

?

Technical parameters:

?

- - - -
Type | Av.CL2 Capacity
?(g/h) | Flow Rate
?(L/h) | Salt Consumption
?(kg/d) | Water
Consumption
(m3/d) | Rated power
?(kw ) | Unite size
?(L×W×H)
(mm) |
CNJY-S-100 | 100 | 13 | 8.4 | 0.31 | 0.6 | 1200×800×1400 |
CNJY-S-200 | 200 | 25 | 16.8 | 0.6 | 1.2 | 1200×800×1400 |
CNJY-S-300 | 300 | 38 | 25.2 | 0.91 | 1.8 | 1200×800×1400 |
CNJY-S-400 | 400 | 50 | 33.6 | 1.2 | 2.4 | 1200×800×1400 |
CNJY-S-500 | 500 | 63 | 42 | 1.51 | 3 | 1200×800×1400 |
- - - -

?
Note:System requirements with salt and water
?

- - - -
Salt requirements: | ? |
Name | Request content( %) |
(NaCl) | >99.3 % |
(Fe) | <0.002% |
(Ca Mg) | <0.023% |
(Mn) | <0.00003% |
(Pb) | <0.0007% |
(Cu) | <0.0003% |
(F) | <0.01% |
? | Water requirements:
1)Operating water temperature:
The temperature between (18?C-23?C)is best. If do not use temperature regulation, please allow the temperature between (10?C-27?C),or a heating?exchanger or chiller equipment to be used for adjust the water temperature.
2)Operating water pressure:
Minimum 0.2 MPa, Maximum 0.35 Mpa, if not in this scope, need to increase a he pressure or vacuum equipment
3)water quality requirements:
pH 6.5 to 8.5
hardness[in calcium carbonate] < 5 ppm (soft water equipment outlet)
COD(Mn) < 1.5 ppm
Fe < 0.2 ?ppm
Mn < 0.01 ppm
Ni < 5 ppm
F <2 ppm
Cu < 5 ppb |
- - - -

?

?

Product introduction:
?
Generation principle:
?
? ? The revolutionary CNJY-S series sodium hypochlorite generator is a newly and for on-site product of NaClO equipment and use for all kinds of needed NaClO disinfected. Its working principle is :the sodium chloride solution under the certain voltage effect of the cell, a series of electrochemical reaction within the cell and the resulting solution is the NaClO solution. The main process can be simplified as follows:
?

The electrode reaction:
anode:2Cl--2e→Cl2
cathode:2H++2e→H2
?
Work flow chart:
?
?

Product components system
?

?
A,inlet water distribution system
Main components: water pressure gauge, water softener, soft water pump, water meter, salt tank, salt water pump and related piping and valves.
?
B,The power control system:
Including control cabinet, rectifier and cable connection.
?
C,Storage and dosing system
Including electrolytic cell, NaClO tank, dosing pump, piping and valves.
?
?
?
Advantage of on-site sodium hypochlorite generator for landscape water treatment :
?
General landscape pool is in the basement, and security is very important, the advantages of CNJY equipment only need to add salt , no pollution, the liquid is safe too.
?
High intelligent degree , truly unattended , without high-tech professionals .
?
Environmental protection, from raw material to the cast and no secondary pollution to the environment. Can meet the higher requirements to the environment.
?
High efficiency , stable equipment is for on site preparation liquid concentration , ?high disinfection effect.

?

DETAILS:

?



?

?

?


?
?
?

cheap prodocuts, china suppliers,

Read More

Previous

Multi Function Long Life Sodium Hypochlorite Production Plant in Large and Medium Size...

Previous

Sodium Hypochlorite Generator Brine Electrolysis For Hosptial Disinfection...

Shanghai Jiayu Environmental Technology Co., LTD

Sodium Hypochlorite Generator,On Site Sodium Hypochlorite Generation,Sodium Hypochlorite Generation System

Address: Xuhui District (East China University of Science and Technology Parks) Huajing Road 1305, Lane on the 10th floor, Block B 3,
Shanghai, Shanghai
China, 200000

Tel: 86-21-61280157
Fax: 86-21-61280157

H5响应式定制设计
26种语言,SEO营销型网站


H5/响应式/营销型企业网站; 26种语言扩展;
覆盖: 英文、法语、德语、西班牙语、葡萄牙语、俄语、阿拉伯语、波斯语、日语、韩语
了解更多