Electronic Data Systems
Description
11KV 12KV Composite Polymer Long Rod Insulator Gray Color
?
?
?
Description:
?
This product is special for badly polluted areas, high mechanical tension load, long span and cpmpact power line. And have features of light weight, small volume, unbreakable, anti-twist and strong explosion protection.
?
?
Product Structure:
?
# # The design of shed adopted unique aerodynamice principle.
# The shed and sheath adopted the whole moulding technique.
# Sheath thicknew accord with the IEC international standard.
# Adopt ERC high-temperature fortified acid-proof model core rod.
# The end seal adopted tie high temperature sulfuration high pressure seal technique, to achieve to the aim of three-protecttion, to ensure the end seal of metal fitting is reliable performance.
# Adopt international advanced aompaction joint technique for metal fitting connection.
# Excellent original material manifacture of products. Whichthehydrophobicity can reach to HC1 level.
# The unique notch design of metal fitting& same thickness of notch, prevent top end discharge.
# The galvanizing coat of metal fitting adopt the technique of rare earth aluminum hot galvanizing, to avoid the zine continue dropout during compaction joint.
?
?
Specifications:
?
?
- - - -
Type | Rated Voltage (KV) | Rated Mechanical Load (KN) | Structure Hight (mm) | Insulation Distance (mm) | Min Nominal Creepage Distance (mm) | Diameter of shed (mm) | 1 Min Power Frequency Wet Withstand Voltage (KV) | Full Wave Lightning Impulse Withstand Voltage (KV) | Unbrella Number |
FXB-12/70CT | 12 | 70 | 370±15 | 210 | 480 | Φ 99 | 42 | 95 | 4 |
- - - -
?
?
Installation Instruction:
?
?
1. The transportation and installation of the insulator shall be taken good care without any throwing or collision, fiction with various sundries(wires, iron plates and tools etc.) and solid material.
?
2. When suspending the composite insulator, the knot shall be made on the attachment at the end. Knot on shed or sheath are strictly prohibted. When the rope has to be contacted with shed or sheath, the contacting area shall be packed with soft cloths.
?
3. Never apply the composite insulator as the assistant tool for the wire distribution and collecttion and collection in case that the insulator can be damages by impact or bending moment.
?
4. Donot step on the insulator shed with foot.
?
5. When installing the grading ring, attention shall be attached on the adjustments to make sure that the ring is vertical with the axial of the insulator. And for opening grading ring, the openning directions at both ends shall be consistent to facilitate the discharging and protect the shed.
?
?
?
FAQ:
?
A. How& acute;s the delivery time?
Depend on your quantity, usually within 20days after receiving deposit
?
?
B. Would you accept OEM/ODM service?
Glad to say that there is planning department, technical department and mould tooling center in
our factory. For the OEM & ODM, it is ok for us if your brand, market shares are great.
?
?
C. Would you offer free sample?
Samples are freely provided and shipping costs is paid on your end usually.
?
?
D What& acute;s your guaranty time?
At least 2 years and depend the product
?
?
E What& acute;s your payment term?
T/T, L/C; other terms is negotiable after further check.
?
Read More
YIXIN ELECTRICAL EQUIPMENT CO.,LTD
Lightning Surge Arrester,Zinc Oxide Surge Arrester,Lightning Arrester
Address: No.218 Wei San Road YueQing Economic Development Zone,
Wenzhou, Zhejiang
China, 325000
Tel: 86-577-62785181
Fax: 86-577-62785182