Filters
Automatic / Munual 2000GF8 HFO Power Plant 3 Ph 500 Rpm / 600 Rpm
According to the design and technical demand
Description
?
Automatic / Munual 2000GF8 HFO Power Plant 3 Ph 500 Rpm / 600 Rpm
?
?
Descrition:
?
These plants are flexible to follow the actual load and produce the necessary electricity typically from diesel oil, heavy fuel oil, bio diesel and bi-fuel. High efficiency, low emissions and proven long-term reliability make our diesel oil power plants, heavy fuel oil power plant, and bi-fuel power plants suitable for baseload applications.?
1.offers a wide range of engines for stationary power generation
2.competitive first-cost, high energy efficiencies and low life-cycle costs underwrite success
3.ranges from baseload power plant, peaking power plant to industrial self-captive power plant in cement, textile, mining or oil and gas industries etc.
4.These engines comfortably meet current emission standards
?
?
Applications:
?
cement, textile, mining or oil and other ?industries etc.
?
?
Competitive Advantage:
?
Our experts in application engineering and project management are the key to achieving very short construction times , builds turn-key power plant with an output up to 60MW
?
?The power fuel can be diesel oil, bio-diesel, heavy fuel oil (HFO) or bi-fuel
?
- - - -
G300 Statinary Generating Sets Main Specification |
Model | 1000GF1 | 1250GF3 | 1350GF4 | 1400GF4 |
Rated power, KW | 1000 | 1250 | 1350 | 1400 |
Overload , KW | 1100 | 1375 | 1485 | 1540 |
Rated voltage, V | 400/415/440/3300/6300/10500/13800 |
Rated current , A | | | | | | | | |
Frequency , Hz | 50 | 60 | 50 | 60 | 50 | 60 | 50 | 60 |
Power factor | 0.8 Lagging |
Phase | 3 |
Diesel engine | G6300ZD6 | G6300ZD8 | G8300ZD6 | G6300ZD10 | G8300ZD10 | G8300ZD8 | G8300ZD10 | G8300ZD8 |
Rated power, KW | 1103 | 1470 | 1471 | 1471 | 1765 | 2000 | 1765 | 2000 |
Rated rev, rpm | 500 | 600 | 500 | 600 | 500 | 600 | 500 | 600 |
Alternator | 3 phase alternator |
voltage fluctuation rate% | <0.5 | <0.5 |
Frequency fluctuation rate, % | <0.5 | <0.5 |
Stable voltage regulating rate, % | ±1.0 | ±1.0 |
Transient voltage regulating rate, % | +20, -15 | +20, -15 |
Stable Frequency fluctuation rate, % | <3 | <0.5 |
Transient frequency regulating rate, % | +12, -10 |
Stablizing time, voltage , S | <4 |
Stablizing time, frequency , S | <3 |
voltage regulating method | automatic and munual |
Frequency regulating method | manual |
starting method | compressed air |
Lubricating method | pressue lubricating? |
Cooking method | water cooling |
coupling | flexible |
Overdimension, mm | 3880*2150*3180 | 8470*2360*3060 |
Weight, Kg | 30000 | 35000 | 38000 |
- - - -
- - - -
G300 Statinary Generating Sets Main Specification |
1500GF6 | 1600GF5 | 1800GF7 | 2000GF8 |
1500 | 1600 | 1800 | 2000 |
1650 | 1760 | 1980 | 2200 |
400/415/440/3300/6300/10500/13800 |
| | | | | | | |
50 | 60 | 50 | 60 | 50 | 60 | 50 | 60 |
0.8 Lagging |
3 |
G8300ZD10 | G8300ZD8 | G8300ZD10 | G8300ZD8 | G8300ZD8 | G8300ZD8 | G8300ZD12 | G8300ZD8 |
1765 | 2000 | 1765 | 2000 | 2000 | 2000 | 2206 | 2000 |
500 | 600 | 500 | 600 | 600 | 600 | 600 | 600 |
3 phase alternator |
<0.5 |
<0.5 |
±1.0 |
20, -15 |
<0.5 |
+20, -15 |
<5 |
<4 |
automatic and munual |
manual |
compressed air |
pressue lubricating? |
water cooling |
flexible |
8470*2360*3060 |
38000 | 42560 |
- - - -
?
?
Remark
?
1.the generator voltage and frequency can be selected
2.rating for the generator set is based on the following standard conditions
air temperature :25℃
total barometric pressure 100kpa
charge air coolant temperature 25℃
relative humidity 30%
If test ambient conditions are not same as the standard ambient conditions, the power and fuel consumptions should be revised according to GB/T6072.1-2000
3.The generator set can operate under overload, intermittently for 1 hour every 12h, the fuel injection quantity is usualy locked in the rated power position
?
- - - -
GN8320 Stationary Generating Sets Main Specification |
Model | 2400GF | 2500GF |
Rated power, KW | 2400 | 2500 |
Overload , KW | 2640 | 2750 |
Rated voltage, V | 400 | 415 | 3300 | 6300 | 10500 | 400 | 415 | 3300 | 6300 | 10500 |
Rated current , A | 4330 | 4174 | 525 | 275 | 165 | 4511 | 4348 | 547 | 172 | 286 |
Frequency , Hz | 50 | 50 |
Power factor | 0.8 Lagging | 0.8 Lagging |
Phase | 3 | 3 |
Diesel engine | GN832000ZD | GN8320ZD |
Rated power, KW | 2648 | 2795 |
Rated rev, rpm | 750 | 750 |
Alternator | 3 phase alternator |
voltage fluctuation rate% | ±1.0 |
Frequency fluctuation rate, % | +12, -10 |
Stable voltage regulating rate, % | 3 |
Transient voltage regulating rate, % | +12, -10 |
Stable Frequency fluctuation rate, % | 4 ? |
Transient frequency regulating rate, % | 5 |
Stabilizing time, voltage , S | +1 |
Stabilizing time, frequency , S | +12, -10 |
voltage regulating method | automatic and manual |
Frequency regulating method | manual |
starting method | compressed air |
Lubricating method | pressure lubricating |
Cooking method | water cooling |
coupling | flexible |
Overdimension, mm | 8950*2570*6050 |
Weight, Kg | 45000 |
- - - -
?
?
Remark
?
1.the generator voltage and frequency can be selected
2.rating for the generator set is based on the following standard conditions
air temperature :25℃
total barometric pressure
charge air coolant temperature
?
?
relative humidity
?
If test ambient conditions are not same as the standard ambient conditions, the power and fuel consumptions should be revised according to GB/T6072.1-2000
3.The generator set can operate under overload, intermittently for 1 hour every 12h, the fuel injection quantity is usualy locked in the rated power position
?
Read More
Previous
Water Cooling Generating Sets HFO Fired Power Plant With G8300 11KV / 750Rpm...
Wuxi Kangwei Environment & Energy Equipment Co., Ltd
Marine Diesel Generator,Diesel Engine Generator Set,Marine Steam Boiler
Address: NO.8, YINGHUI ROAD, MASHAN TECHNOLOGICAL,
wuxi, jiangsu
China, 214000
Tel: 86-510-85990011
Fax: 86-510-85115375